Wagner SprayTech 558052 User Manual

Page of 36
ProSpray 3.29 • 3.31
9
GB
 
Starting operation
4
4.2 
Control Panel Indicators
The following is a description of the control panel indicators.
Pressure
Indicator
Service
Indicator
Pressure Indicator
The pressure indicator shows the current operating pressure of the 
sprayer. It has three different indications: blinking yellow, solid
yellow, and solid green.
Blinking yellow
When the pressure indicator is blinking yellow, the sprayer is 
operating between 0 and 1.4 MPa (14 bar).  A blinking yellow 
pressure indicator means:
•  The sprayer is plugged in and turned “ON”
•  The sprayer is at priming pressure (little or no pressure)
•  It is safe to move the relief valve between positions
•  It is safe to change or replace the spray tip
i
If the pressure indicator begins blinking yellow when 
the pressure control knob is set at a higher pressure 
and the relief valve is in the SPRAy position, either 
the spray tip is worn or the sprayer is in need of 
service/repair.
Solid yellow
When the pressure indicator is solid yellow, the sprayer is operating 
between 1.4 MPa (14 bar) and 12 MPa (120 bar).  A solid yellow 
pressure indicator means:
•  The sprayer is at the proper pressure setting for spraying stain,
lacquer, varnish, and multi-colors
Solid Green
When the pressure indicator is solid green, the sprayer is operating 
between 12 MPa (120 bar) and 23 MPa (230 bar).  A solid green 
pressure indicator means:
•  The sprayer is at the proper pressure setting for spraying oil-
based and latex house paints
•  The sprayer is operating at peak performance at a high
pressure setting
•  If the pressure indicator goes to solid yellow when the
pressure is set so that it starts at solid green, it indicates one of 
the following:
 a. 
Tip Wear Indicator — when spraying with latex or at high 
pressure the solid yellow appears.  This means the tip is 
worn and needs to be replaced.
 b. 
tip too Large — when a tip that is too large for the sprayer 
is put in the gun, the pressure indicator will turn from solid 
green to solid yellow.
 c. 
Fluid Section Wear — if a solid yellow pressure indicator 
appears when using a new tip and the pressure is set at 
maximum, service may be required (worn packings, worn 
piston, stuck valve, etc...).
Service Indicator
The Service indicator is on when the motor is commanded to run.  
This indicator is used by service centers to troubleshoot motor 
problems.
4.3 
Pressure control knob settings (Fig. 6)
  1.  Minimum pressure setting
 2.  Black zone – no pressure generation
 3.  Blue zone – pulsating pressure for cleaning
1
2
3
4.4 
Connection to the mains network
Attention
The unit must be connected to an appropriately-
grounded safety outlet.
Before connecting the unit to the mains supply, ensure that the line 
voltage matches that specified on the unit’s rating plate.
The connection must be equipped with a residual current protective 
device with INF ≤ 30 mA.