Super Finish 23 PLUS
 
GB
REPAIRS AT THE UNIT
10.4 
PRESSURE CONTROL VALVE
Only have the pressure control valve (1) re-
placed by the customer service.
The max. operating pressure has to be reset 
by the customer service.
1
7
2
3 4
5
6
1
10.3 
OUTLET VALVE
1.  Use a 22 mm wrench to screw the outlet valve from the 
paint section.
2.  Carefully pull of the clasp (1) using the enclosed screw-
driver. The compression spring (2) presses ball (4) and 
valve seat (5) out.
3.  Clean or replace the components.
4.  Check the O-ring (7) for damage.
5.  Check the installation position when mounting the spring 
support ring (3) (clipped onto spring (2)), outlet valve seat 
(5) and seal (6), refer to figure.