6    Troubleshooting 
   
 
    Type of malfunction 
Possible causes 
Correction 
   
Drops form on the trigger 
–  The needle gasket 5 is 
worn respectively loose 
and must slightly be 
retightened. 
• For that purpose 
remove needle/valve 
cartridge, see 
section 4.3. Then 
unscrew screw at the 
valve body 4 and take 
out needle driver 
(squared bolt). Using a 
small screw driver turn 
stuffing box 6 gently 
clockwise and try if 
needle is sliding 
smoothly again within 
the tightened gasket. 
   
Drops form on the nozzle 
–  Either needle or nozzle 
is worn. 
–  Needle is not closed 
properly e.g. because 
of particle residues 
within nozzle. 
• Replace needle or 
nozzle. 
•  Clean the needle/valve 
cartridge with solvent, 
see section 5. 
   
There is an uneven and 
not steady spray jet 
–  Dirt residue within air 
cap. 
–  Nozzle is not correctly 
screwed in. 
•  Clean air cap with 
solvent. 
•  Make sure that nozzle 
is screwed in tight. 
   
Air blowing constantly 
although trigger is 
released. 
– O-ring 9 and/or 
washer 10 worn. 
–  Needle nuts are not 
counter-screwed in 
correct position, see 
section 5.3. 
• Change O-ring and/or 
washer. 
   
Drops form on the 
extension at the applicator 
and/or the spray head. 
– O-rings are worn. 
• Change O-rings, see 
section 7.2.