3   Technical Data 
 
 
 
Quality: If the required quality 
is not achieved, install a 
LOCTITE separator. 
Filtered 10 µm, oil-free, non-condensing. 
 
Accessory Order No. 97714 
 
Max. Air Pressure 
6 bar (87 PSI) 
 
Max. Agent Pressure 
1.5 bar (29 PSI), 
see operating manual pressure pot. 
 
Air Consumption 
App. 90 l/min at 3 bar (43 PSI) and 0.5 mm 
nozzle 
 
Weight 
0.240 kg 
 
Length Duo Tube 
~ 3 m (~10 ft) 
 
 
4   Setup and Operation 
 
 
 
 
 
Pay attention to the safety instructions in section 1.4 “For your Safety”. 
4.1  Setup 
 
If fluid output requires to be regulated individually, apply needle regulator with 
counter nut 15 for quantity of fluid flow. To spray with a spray applicator a definite 
volume of atomizing air and a definite pressure of materials is needed. Activating 
the trigger will open the needle and the material flows out of from the nozzle. The air 
pressure atomizes the material and forms it to a jet. 
The needle function is: Opening by trigger and closing by spring force. 
 
•  Connect duo tube to pressure pot or other means of feeding fluid and to main air 
supply. 
Clear tube: for agents, connection M 17
Blue tube: for air pressure, connection AIR 16
•  Set air pressure to required spray droplet size by the regulator for pressurized air 
at the pressure pot, see operating manual pressure pot. 
•  Set agent pressure to required material outlet and spray droplet size by the 
regulator for agents at the pressure pot, see operating manual pressure pot.