Circuit Requirements
This machine must be connected to the correct size and 
type of power supply circuit, or fire or electrical damage 
may occur. Read through this section to determine if an 
adequate power supply circuit is available. If a correct 
circuit is not available, a qualified electrician MUST install 
one before you can connect the machine to power.
A power supply circuit includes all electrical equipment 
between the breaker box or fuse panel in the building 
and the machine. The power supply circuit used for 
this machine must be sized to safely handle the full-
load current drawn from the machine for an extended 
period of time. (If this machine is connected to a circuit 
protected by fuses, use a time delay fuse marked D.)
Circuit Requirements for 110V
This machine can be converted to operate on a 110V 
power supply (details about voltage conversion can be 
found later in this manual). The 110V power supply circuit 
must have a verified ground and meet the requirements 
that follow:
Circuit Type ............... 110V/120V, 60 Hz, Single-Phase
Circuit Size ............................................. 15 Amps
Plug/Receptacle .................................... NEMA 5-15
Full-Load Current Rating
The full-load current rating is the amperage a machine 
draws at 100% of the rated output power. On machines 
with multiple motors, this is the amperage drawn by the 
largest motor or sum of all motors and electrical devices 
that might operate at one time during normal operations.
Full-Load Current Rating at 110V .................. 12 Amps
The  machine  must  be  properly  set  up 
before  it  is  safe  to  operate.  DO  NOT 
connect  this  machine  to  the  power 
source  until  instructed  to  do  later  in 
this manual.
Incorrectly  wiring  or  grounding  this 
machine can cause electrocution, fire, 
or machine damage. To reduce this risk, 
only  a  qualified  electrician  or  service 
personnel  should  do  any  required 
electrical work for this machine.
NOTICE 
The circuit requirements listed in this 
manual  apply  to  a  dedicated  circuit—
where only one machine will be running 
at  a  time.  If  this  machine  will  be 
connected  to  a  shared  circuit  where 
multiple  machines  will  be  running  at 
the  same  time,  consult  a  qualified 
electrician to ensure that the circuit is 
properly sized for safe operation.