Grizzly G0454 User Manual

Page of 72
-34-
g0453/g0454 (Mfg. since 3/08)
Motor & Electrical (continued)
symptom
possible Cause
possible solution
Machine has 
vibration or noisy 
operation.
8.  Motor fan rubbing on fan cover.
9.  Bed rollers protruding unevenly.
10. Motor bearings at fault.
11. Cutterhead bearings at fault.
12. Centrifugal switch is at fault.
13. Chip deflector hitting knives.
8.  Fix/replace fan cover; replace loose/damaged fan.
9.  Adjust bed rollers (
Page 26). 
10. test by rotating shaft; rotational grinding/loose shaft 
requires bearing replacement.
11. replace bearing(s)/realign cutterhead.
12. replace switch.
13. Check/replace chip deflector and realign (
Page 43).
Machine Operation
symptom
possible Cause
possible solution
Excessive snipe 
(gouge at the end of 
the workpiece that 
is uneven with the 
rest of the cut).
Note: A small 
amount of snipe 
is inevitable 
with all types of 
planers—the key is 
to minimize it.
1.  one  or  both  of  the  bed  rollers  are  set  too 
high.
2.  rear extension wing slopes down or is not 
level with main table.
3.  Chip breaker or pressure bar set too low.
4.  Workpiece  is  not  properly  supported  as  it 
leaves the planer.
1.  lower the bed rollers (
Page 26).
2.  Adjust the rear extension wing set screws to make 
the extension level with the main table (
Page 18).
3.  raise the height of the chip breaker or pressure bar 
(
Page 40).
4.  use  an  assistant  or  roller  beds/stands  to  properly 
support the workpiece as it leaves the planer.
Workpiece stops/
slows in the middle 
of the cut.
1.  depth of cut too deep.
2.  pitch  and  glue  build-up  on  planer 
components. 
3.  one  or  both  of  the  bed  rollers  are  set  too 
low or too high.
4.  Chip breaker or pressure bar set too low.
5.  Feed rollers set too low or too high.
1.  reduce the depth of cut (
Page 26).
2.  Clean planer components with a pitch/resin dissolving 
solvent. 
3.  lower/raise the bed rollers (
Page 26).
4.  raise the height of the chip breaker or pressure bar 
(
Page 40).
5.  Adjust  the  feed  rollers  to  the  correct  height  (
Page 
40).
Consistent chipping 
pattern.
1.  Knots  or  conflicting  grain  direction  in 
workpiece.
2.  nicked or chipped knife.
3.  Feed rate too fast.
4.  depth of cut too deep.
5.  Misaligned chip breaker.
1.  inspect workpiece for knots and grain direction; use 
only clean stock (
Page 24).
2.  sharpen/replace knife (
Page 36).
3.  reduce feed rate (
Page 25).
4.  reduce the depth of cut (
Page 26).
5.  Adjust  both  sides  of  chip  breaker  to  the  correct 
height (
Page 40).