Grizzly G0597 User Manual

Page of 32
-8-
G0596-G0599 Industrial Bench Grinders
In  the  event  of  an  electrical  short,  grounding 
reduces the risk of electric shock. The grounding 
wire in the power cord must be properly connect-
ed to the grounding prong on the plug; likewise, 
the outlet must be properly installed and ground-
ed.  All  electrical  connections  must  be  made  in 
accordance with local codes and ordinances.
We  do  not  recommend  the  use  of  extension 
cords.  Instead,  arrange  the  placement  of  your 
equipment  and  the  installed  wiring  to  eliminate 
the need for extension cords.
If you find it absolutely necessary to use an exten-
sion cord with your machine, the extension cord 
must also contain a ground wire and plug pin.
110V Operation
Use at least a 12 gauge cord that does not exceed 
50 feet in length!
220V Operation
Use at least a 12 gauge cord that does not exceed 
50 feet in length!
Extension Cords
Grounding
This machine must have a ground prong in 
the plug to help ensure that it is grounded. 
DO  NOT  remove  ground  prong  from  plug 
to  fit  into  a  two-pronged  outlet!  If  the  plug 
will not fit the outlet, have the proper outlet 
installed by a qualified electrician.
When  using  a  phase  converter  for  3-phase,  the 
power  from  the  manufactured  power  leg  (some-
times called the wild wire) can fluctuate. Connect 
the manufactured power leg  to the S terminal to 
prevent damage. The wire from the S terminal can 
handle some fluctuation because it goes directly 
to  the  motor.  The  power  going  to  the  R  and  T 
terminals  goes  to  the  transformer  and  must  be 
consistent to prevent damage.
Phase Converter
Figure 3. A locking shut-off switch near the 
machine.