SECTION 2: CIRCUIT REQUIREMENTS
Amperage Draw
The motor for your machine may draw the follow-
ing amps at maximum load.
G0596 at 110V Single-Phase ............... 14 Amps 
G0597 at 220V Single-Phase .............. 8.5 Amps
G0598 at 220V Single-Phase ............... 12 Amps 
G0599 at 220V 3-Phase ....................... 10 Amps
Circuit Requirements
We  recommend  connecting  this  machine  to  a 
dedicated circuit with a verified ground, using the 
circuit breaker size given below. Never replace a 
circuit breaker with one of higher amperage with-
out  consulting  a  qualified  electrician  to  ensure 
compliance with wiring codes. 
If you are unsure 
about  the  wiring  codes  in  your  area  or  you 
plan to connect your machine to a shared cir-
cuit, you may create a fire hazard—consult a 
qualified electrician to reduce this risk.
G0596 at 110V ................15 Amp Circuit Breaker
G0597 at 220V ...............15 Amp Circuit Breaker
G0598 at 220V ...............15 Amp Circuit Breaker
G0599 at 220V 3-Phase .15 Amp Circuit Breaker
Figure 1. NEMA 6-15 plug and receptacle.
Figure 2. NEMA 15-15R plug and receptacle.
Plug Type
With  the  exception  of  the  G0596,  the  cord  set 
enclosed does not have a plug as the style of plug 
you require will depend upon the type of service 
you  currently  have  or  plan  to  install.  We  recom-
mend using the following plugs for your machine 
on a dedicated circuit only (see 
Figures 1–3 for 
examples):
G0597 at 220V ......................... NEMA 6-15 Plug
G0598 at 220V ......................... NEMA 6-15 Plug
G0599 at 220V 3-Phase .. NEMA 15-15R Plug or
..220V Locking Shut-Off Switch (recommended)
�������������
�������
��������
������
��������
����������