Pioneer PX-42VP5 User Manual

Page of 82
 
 
16 
04. VOLUME Gain Data
 
Function 
The external control equipment changes the VOLUME gain data of the plasma 
monitor. 
Transmission Data 
  DFH   80H   60H   7FH   03H   DATA00    DATA01    DATA02  CKS 
 
DATA00: USER SOUND Gain Flag    05H 
 
DATA01: VOLUME Gain Flag   
 
01H 
 
DATA02: VOLUME Gain   
 
00H: Step0 
 
 
 
  : 
 
 
0AH: Step10 (Default) 
 
 
  : 
 
 
2AH: Step42 
ACK 
  7FH   60H   80H   7FH   02H   DATA00    DATA01    CKS 
 
DATA00: USER SOUND Gain Flag     
05H 
 
DATA01: VOLUME Gain Flag 
 
01H 
 
05. AUDIO Mute ON 
Function 
The  external  control  equipment  switches  on  AUDIO  Mute  of  the  plasma 
monitor. 
Transmission Data 
  9FH   80H   60H   3EH   00H   CKS 
ACK 
  3FH   60H   80H   3EH   00H   CKS 
 
06. AUDIO Mute OFF 
Function 
The  external  control  equipment  switches  off  AUDIO  Mute  of  the  plasma 
monitor. 
Transmission Data 
  9FH   80H   60H   3FH   00H   CKS 
ACK 
  3FH   60H   80H   3FH   00H   CKS