07. CONTRAST Gain Data
 
Function 
The  external  control  equipment  changes  the  CONTRAST  gain  data  of  the 
plasma c 
Transmission Data 
  DFH   80H   60H   7FH   03H   DATA00    DATA01    DATA02  CKS 
 
DATA00 : USER PICTURE Gain Flag   
01H 
 
DATA01 : CONTRAST Gain Flag   
 
07H 
 
DATA02 : CONTRAST Gain   
 
CCH : -52 
 
 
 
 
 
 
 
FFH : -01 
 
 
 
00H : 0 
 
 
 
01H : +01 
 
 
 
 
 
 
14H : +20 
ACK 
  7FH   60H   80H   7FH   02H   DATA00    DATA01    CKS 
 
DATA00: USER PICTURE Gain Flag   
01H 
 
DATA01: CONTRAST Gain Flag   
 
07H 
 
08. BRIGHT Gain Data 
Function 
The external control equipment changes the BRIGHT gain data of the plasma 
monitor. 
Transmission Data 
  DFH   80H   60H   7FH   03H   DATA00    DATA01    DATA02  CKS 
 
DATA00 : USER PICTURE Gain Flag   
01H 
 
DATA01 : BRIGHT Gain Flag   
 
08H 
 
DATA02 : BRIGHT Gain   
 
E0H : -32 
 
 
 
  : 
 
 
FFH : -01 
 
 
00H : 0 
 
 
01H : +01 
 
 
  : 
 
 
20H : +32 
ACK 
  7FH   60H   80H   7FH   02H   DATA00  DATA01    CKS