31. POWER MGT Select
   
Function 
The external control equipment switches on or off the POWER MANAGEMENT 
of the plasma monitor. 
Transmission Data 
  DFH   80H   60H   1AH   02H   DATA00    DATA01    CKS 
 
DATA00 : POWER MGT Select 
03H 
 
DATA01    
 
 
 
 
01H : ON 
 
 
 
 
 
 
 
 
02H : OFF 
ACK 
  7FH   60H   80H   1AH   02H   DATA00    DATA01    CKS 
 
DATA00 : POWER MGT Select 
03H 
 
DATA01    
 
 
 
 
01H : ON 
 
 
 
 
 
 
 
 
02H : OFF 
 
 
32. GRAY LEVEL Set
   
Function 
The external control equipment sets the GRAY LEVEL of the plasma monitor. 
Transmission Data 
  DFH   80H   60H   C6H   01H   DATA00 CKS 
 
DATA00 : GRAY LEVEL 
00H : 0 
 
  : 
 
0FH : 15 
ACK 
  7FH   60H   80H   C6H   01H   DATA00 CKS 
 
DATA00 : GRAY LEVEL 
00H : 0 
 
  : 
 
0FH : 15