35. INVERSE Set
 
Function 
The  external  control  equipment  sets  the  INVERSE  (inverse  of  image 
brightness) and the WHITE of the plasma monitor. 
Transmission Data 
  DFH   80H   60H   C7H   03H   DATA00 DATA01 DATA02 CKS 
 
DATA00: INVERSE/WHITE   
00H : No operation 
 
 
01H : ON (INVERSE) 
 
 
02H : OFF 
 
 
03H : WHITE   
 
DATA01 : WORKING TIME 
00H : ON 
 
01H: 03M (minutes) 
 
02H: 06M (minutes) 
 
    : 
 
FFH: 12H (hours) and 45M (minutes) 
 
DATA02 : WAITING TIME 
01H: 03M (minutes) 
 
 
02H: 06M (minutes) 
 
    : 
 
 
FFH: 12H (hours) and 45M (minutes) 
ACK 
  3FH   60H   80H   C7H   00H  CKS 
 
 
 
NOTE: The WORKING TIME and the WAITING TIME can be set in
units of 3 minutes. 
Example: 03H=9 minutes 
                  1EH=1 hour and 30 minutes