Pioneer PX-42VM5 User Manual

Page of 82
 
 
35 
36. SCREEN WIPER Set
 
Function 
The  external  control  equipment  sets  the  SCREEN  WIPER  of  the  plasma 
monitor. 
Transmission Data 
  DFH   80H   60H   C8H   04H   DATA00 to DATA03    CKS 
 
DATA00 : SCREEN WIPER 
00H : No operation 
 
 
01H : ON   
 
 
02H : OFF   
 
DATA01 : WORKING TIME 
00H : ON 
 
01H: 03M (minutes) 
 
02H: 06M (minutes) 
 
    : 
 
FFH: 12H (hours) and 45M (minutes) 
 
DATA02 : WAITING TIME 
01H: 03M (minutes) 
 
 
02H: 06M (minutes) 
 
    : 
 
 
FFH: 12H (hours) and 45M (minutes) 
 
DATA03 : SPEED 
01H : 1 
 
    : 
 
 
05H : 5 
ACK 
  3FH   60H   80H   C8H   00H  CKS 
 
 
 
 
 
 
 
 
 
NOTE: The WORKING TIME and the WAITING TIME can be set in
units of 3 minutes. 
Example: 03H=9 minutes 
                  1EH=1 hour and 30 minutes