Setup 
 
 
COLORado™ 1-Tri IP User Manual Rev. 01c 
 
-7- 
DMX Linking 
 
You may link any COLORado™ 1-Tri IP  fixture to a DMX controller using a standard 
DMX serial connection. If using other DMX compatible fixtures with a COLORado™ 1-
Tri IP fixture, it is possible to control them individually with a single DMX controller. 
If you are not familiar with the DMX standard, or if you need information about the DMX 
cables needed to link the COLORado™ 1-Tri IP  fixture to a DMX controller, you may 
download the “DMX Primer” document from the CHAUVET® Web site. 
   
 
 
 
The  COLORado™ 1-Tri IP  comes with two adapter cables, one from proprietary 
IP66 to 3-pin DMX In and the other from proprietary IP66 to 3-pin DMX Out. In 
addition, it comes with a signal linking cable with proprietary IP66 connectors on 
both ends.
 
   
 
DMX Modes 
 
The COLORado™ 1-Tri IP uses the standard DMX data connection for its DMX modes, 
TOURARC1AR1+DAR1+S, and HSV.  
You will find information about these DMX modes in the Introduction  chapter (brief 
description), the Operation Instructions  chapter (configuration details), and the DMX 
Values
 section (individual channel values). 
   
 
Master/Slave 
Connectivity 
 
The Master/Slave mode allows a COLORado™ 1-Tri IP  fixture to control one  or  more 
COLORado™ 1-Tri IP fixtures without a DMX controller. The controlling fixture becomes 
the “master” when running an auto  or  custom  program  as well as when in STATIC 
mode. The controlled fixtures are the “slaves” and you must set them to “SLAVE” mode 
from their respective control panels. During the Master/Slave operation, the slave 
fixtures will operate in unison with the master fixture.  
The master and slave fixtures link to each other using the standard DMX serial 
connection. If you are not familiar with the Master/Slave connectivity, you may download 
the “DMX Primer” document from the CHAUVET® Web site. 
 
 
 
 
 
DO NOT connect a DMX controller to the fixtures operating in Master/Slave mode. 
Otherwise, the signals from the DMX controller may interfere with the signals from 
the master unit. 
   
 
 
 
The  Operation  chapter of this manual provides detailed instructions on how to 
configure the Master and Slave units.  
   
 
ID Addressing
 
 
The  COLORado™ 1-Tri IP  uses the ID Addressing feature to increase the number of 
addressable fixtures in the same DMX universe when in the TOUR personality. Refer to 
the  Operation  chapter in this manual to learn in detail how to configure the 
COLORado™ 1-Tri IP fixtures when using ID Addressing. If you are not familiar with the 
various connection methods when using ID Addressing, you may download the “DMX 
Primer” document from the CHAUVET® Web site.