Operation 
 
 
COLORado™ 1-Tri IP User Manual Rev. 01c 
 
-11- 
Continued from previous page 
 
Color Adjustment 
 
The COLOR setting determines how the COLORado™ 1-Tri IP displays the white color 
when the Red, Green, and Blue faders are all at the “255” value. 
1)  Go to SET > Color
2)  Select OFFRGBW, or UC
 
 
 
   
Setting 
Description 
OFF 
When R, G, and B are “255,” the output will be at its maximum. 
RGBW 
When R, G, and B are “255,” CAL2 will determine the output. 
UC 
When R, G, and B are “255,” the output will match that of fixtures from 
previous generations. 
   
 
Dimmer Curves 
 
This setting determines how the output of the COLORado™ 1-Tri IP follows the position 
of the Dimmer fader, as well as the Red, Green, and Blue faders. 
1)  Go to SET > Dim
2)  Select a dimmer curve (OffDim1Dim2Dim3, or Dim4). 
 
 
 
   
Setting 
Description 
OFF 
The output is proportional to the faders’ position (linear) 
Dim1 
The output is not proportional (fastest) 
Dim2 
The output is not proportional (fast) 
Dim3 
The output is not proportional (slow) 
Dim4 
The output is not proportional (slowest) 
   
 
Control Panel Lock 
 
This setting allows the user to activate or disable the control panel lock, which keeps 
non-authorized personnel from changing the fixture’s settings. 
1)  Go to KEY
2)  Select On/ Off
 
 
 
 
 
When the control panel lock is active, the fixture will prompt the user to enter the 
password  after 30 seconds of control panel inactivity or after turning on the 
fixture. 
 
 
 
   
After being prompted to enter the password: 
1)  Press <UP><DOWN><UP><DOWN>, and <ENTER>.  
   
 
Program Upload 
 
This option allows the user to copy the custom programs of one COLORado™ 1-Tri IP 
fixture onto other COLORado™ 1-Tri IP fixtures by using the Master/Slave method. 
1)   Configure and connect the fixtures in a Master/Slave arrangement, where the 
master unit has the custom programs you want to transfer onto the slave units. 
2)  At the master unit, go to SET > UPLD
3)  When prompted, enter the master access password as shown in Control Panel 
Lock
4)  Wait for the upload process to finish before disconnecting the fixtures. 
During and after the upload, the master and slave units will visually indicate the status of 
the process, as follows: 
 
 
 
   
Color 
Meaning 
Yellow 
The upload process is running 
Red 
The upload failed due to an error 
Green 
The upload finished successfully 
   
 
 
 
 
 
 
 
 
 
Continues on the next page