Chauvet 1-TRI IP User Manual

Page of 28
Operation 
 
 
-12- 
 
COLORado™ 1-Tri IP User Manual Rev. 01c 
Continued from previous page 
 
Reset 
 
This setting allows the user to reset the COLORado™ 1-Tri IP  fixture to its default 
values, including the custom programs.  
1)  Go to SET> REST
2)  When prompted, enter the master access password as shown in Control Panel 
Lock
3)  Wait for the reset process to finish. 
   
 
Whites Setting 
 
This setting allows the user to edit the temperature of the 11 white colors used in the 
Macros channel. The 11 pre-set whites are configurable. 
1)  Go to CAL1
2)  Select a white color (WT. 1~11). 
3)  Select a color (RedGreen, or Blue). 
4)  Select a color value (0~255). 
5)  Repeat for the other colors (RedGreen, or Blue). 
6)  Repeat for the other white colors (WT. 1~11). 
   
 
White Calibration 
 
This setting allows the user to select the white color shown by the COLORado™ 1-Tri IP 
when the color setting is RGBW and the DMX controller’s Red, Green, and Blue faders 
are set to “255”. 
1)  Go to CAL2 > RGBW
2)  Select a color (RedGreen, or Blue). 
3)  Select a color value (0~255). 
4)  Repeat for the other colors (RedGreen, or Blue).