Smeg cooktop User Manual

Page of 25
 
 
Instructions for the installer 
 
6.  ADAPTATION TO DIFFERENT TYPES OF GAS 
 
 
 
 
 
Before performing any cleaning or maintenance work, detach the 
appliance from the electrical socket.
 
The hob has been inspected for NG  natural gas at a pressure of 1.0 
kPa. For functioning with other types of gas the nozzles must be replaced 
and the primary air adjusted.  
To replace the nozzles and regulate the burners, you have to remove the 
top as described in the following paragraph. 
 
6.1 Removing the hob 
1.  Remove all the knobs, the grids, the burner caps and the flame-caps; 
2.  remove the screws and the nuts A that secure the burner supports; 
3. remove 
plates 
B
4.  lift the hob from its seat; 
5.  replace the burner nozzles in accordance with the reference gas 
chart; 
6.  regulate the primary air as described in paragraph “6.2 Regulation 
for LPG”. 
 
 
 
 
 
15