Senco PC2017 User Manual

Page of 16
10 
 
 
 
 
      
 
               Senco
®
 Gasoline Air Compressor Manual  2004
INITIAL SET-UP:
1.  Read safety warnings before setting-up air compressor.  
2.  Ensure the oil level is above the minimum notch and below the maximum notch on the dipstick.  If low, add  
 
Senco
®
 part number PC0344 compressor pump oil.
LOCATION:
CAUTION
In order to avoid damaging the air compressor, do not incline the air compressor transversely 
or longitudinally more than 10°.
1.  Place air compressor at least 12 inches away from obstacles that may prevent proper ventilation.  Do not place  
 
air compressor in an area:
 
-where there is evidence of oil or gas leaks.
 
-where flammable gas vapors or materials may be present.
WARNING
Serious injury or death may occur if electrical sparks from motor and pressure switch come in 
contact with flammable vapors, combustible dust, gases or other combustible materials.
When using the air compressor for spray painting, place the air compressor as far away 
from the work area as possible, using extra air hoses instead of extension cords.  
 
-where air temperatures fall below 32°F or exceed 104°F.
 
-where extremely dirty air or water could be drawn into the air compressor.
GASOLINE ENGINE:
DANGER
Do not place unit in an area where flammable gas vapors may be present.  A spark could 
cause an explosion or fire.
DANGER
Do not smoke while fueling!
Do not fill fuel tank while compressor is running or hot.  Allow air compressor and engine 
to cool down for two minutes before refueling.
Do not fill fuel tank to point of overflowing.  Allow approximately 1/4" of head space for fuel 
expansion.
PREPARATION
WARNING
Always store fuel away from the air compressor while it is running or hot.
WARNING
Do not operate in an enclosed area.  Use this product only in well ventilated areas!  The 
exhaust from the engine contains carbon monoxide, a poisonous, odorless and invisible 
gas.  Breathing the gas can cause serious injury, illness and possible death.
 
1.  Review "Risk of Fire or Explosion" pg. 4 before fueling.
2.  Read  the  engine  manual  accompanying  this  air  compressor  for  correct  engine  start-up  maintenance  
 
procedures.
3.  Read and understand the safety labels located on the air compressor.
4.  A minimum of 86 octane fuel is recommended for use with this air compressor.  Do not mix oil with    
 
gasoline.
5.  Use of clean, fresh, lead free gasoline is recommended.  Leaded gasoline may be used if lead free is not 
 
available. Do not use gasoline containing methanol or alcohol.
6.  Check the engine oil level before starting.  (See engine manual.)
7.  Fill the fuel tank according to the engine manual instruction.
8.  Refer to the engine manual for all necessary maintenance and adjustments.