AIR INTAKE FILTER:  This filter 
is designed to clean air coming 
into  the  pump.    To  ensure  the 
pump  continually  receives  a 
clean,  cool,  dry  air  supply  this 
filter must always be clean and 
ventilation  opening  free  from 
obstructions.  Replace filter when 
necessary.
AIR COMPRESSOR PUMP:  To 
compress air, the pistons move 
up  and  down  in  the  cylinders.  
On the downstroke, air is drawn 
in through the air intake valves 
while the exhaust valves remain 
closed.  On the upstroke, air is 
compressed, the intake valves 
close  and  compressed  air  is 
forced out through the exhaust 
valves, into the discharge line, 
through the pilot valve and into 
the air tank.
PILOT VALVE:  When the toggle 
is in the upright position, all air 
from the air compressor is vented 
through  the  discharge  muffler.  
This gives an easy start feature.  
For normal operation, the toggle 
is in the 90° position.
SAFETY  RELIEF  VALVE:  
This  valve  is  designed  to  
prevent  system  failures  by  
relieving  pressure  from  the 
system  when  the  compressed 
air  reaches  a  predetermined 
level.    The  valve  is  preset  by 
the  manufacturer  and  must 
not  be  modified  in  any  way.  
To  verify  the  valve  is  working  
properly, pull on the ring.  Air pres-
sure should escape.  When the 
ring is released, it will reseat.  
AIR  TANK  DRAIN  VALVE:  
The  drain  valve  is  used  to  
remove  moisture  from  the 
air tank(s) after the air com-
pressor  is  shut  off.   
NEVER  
attempt  to  open  the  drain 
valve  when  more  than  10 
PSI of air pressure is in the 
air tank!  To open the drain 
valve, turn the knob counter-
clockwise.  
AIR  TANK  PRESSURE 
GAUGE:    The  air  tank  
pressure gauge indicates the 
reserve air pressure in the air 
tank (s).
PRESSURE  REGULATOR:  
The air pressure coming from 
the air tank is controlled by the 
regulator knob.  Turn the pres-
sure regulation knob clockwise 
to  increase  discharge  pres-
sure,  and  counterclockwise 
to  decrease  discharge  pres-
sure.
O U T L E T   P R E S S U R E 
GAUGE:  The outlet pressure 
gauge indicates the air pres-
sure available at the outlet side 
of the regulator.  This pressure 
is controlled by the regulator 
and is always less or equal to 
the air tank pressure.
OIL SIGHT GLASS:  The oil sight 
glass will register the amount of 
oil in the pump.   Ensure the oil 
level in the air compressor pump 
is adequate. If low, add SAE-30W 
non-detergent oil.
 
PC2017 FEATURES REVIEW