Intel E8200 BX80570E8200A User Manual

Product codes
BX80570E8200A
Page of 128
 
Processor Thermal/Mechanical Information 
 
 
Thermal and Mechanical Design Guidelines   
 25 
In addition to passive heatsinks, fan heatsinks and system fans are other solutions 
that exist for cooling integrated circuit devices. For example, ducted blowers, heat 
pipes and liquid cooling are all capable of dissipating additional heat. Due to their 
varying attributes, each of these solutions may be appropriate for a particular system 
implementation.  
To develop a reliable, cost-effective thermal solution, thermal characterization and 
simulation should be carried out at the entire system level, accounting for the thermal 
requirements of each component. In addition, acoustic noise constraints may limit the 
size, number, placement, and types of fans that can be used in a particular design. 
To ease the burden on thermal solutions, the Thermal Monitor feature and associated 
logic have been integrated into the silicon of the processor. By taking advantage of 
the Thermal Monitor feature, system designers may reduce thermal solution cost by 
designing to TDP instead of maximum power. Thermal Monitor attempts to protect the 
processor during sustained workload above TDP. Implementation options and 
recommendations are described in Chapter 
4. 
2.4.3 
Summary 
In summary, considerations in heatsink design include:  
  The local ambient temperature T
A
 at the heatsink, which is a function of chassis 
design. 
  The thermal design power (TDP) of the processor, and the corresponding 
maximum T
C
 as calculated from the thermal profile. These parameters are usually 
combined in a single lump cooling performance parameter, 
CA
 (case to air 
thermal characterization parameter). More information on the definition and the 
use of 
CA
 is given Section 
  Heatsink interface to IHS surface characteristics, including flatness and roughness. 
  The performance of the thermal interface material used between the heatsink and 
the IHS. 
  The required heatsink clip static load, between 18 lbf to 70 lbf throughout the life 
of the product (Refer to Section 
2.1.2.2 for further information). 
  Surface area of the heatsink. 
  Heatsink material and technology. 
  Volume of airflow over the heatsink surface area. 
  Development of airflow entering and within the heatsink area. 
  Physical volumetric constraints placed by the system 
2.5 
System Integration Considerations 
Manufacturing with Intel
®
 Components using 775–Land LGA Package and LGA775 
Socket documentation provides Best Known Methods for all aspects LGA775 socket 
based platforms and systems manufacturing. Of particular interest for package and 
heatsink installation and removal is the System Assembly module. A video covering 
system integration is also available. Contact your Intel field sales representative for 
further information. 
§