STEP
Fill fry tank with oil and 
then turn power on
1
STEP
Programming modES
2-7
www.VulcanHart.com • Fryer Technical Support: 1-800-814-2028
To SToP a TimEr oncE ThE counTdown SEquEncE haS STarTEd:
Press and hold the timer 
button until timer is reset and 
flashing light goes OFF.
LEFT TIMER 
BUTTON
RIGHT TIMER 
BUTTON
LEFT
RIGHT
LIGHTS
F-32912  (January 2007)
To 
unLocK
this control you  
must quickly press the 
buttons while the 
word ‘LocKEd’ is 
displayed
LEFT   LEFT  righT  righT
unLocK codE
Programming in 7 Easy Steps
 
(for revisions V3.00 or higher) 
Display will scroll through VULCAN 
 ➤
 
 
FRYERS 
 ➤
 
 
Rev. No.  
 
 
MELT CYCLE LIQUID
SoLid STaTE conTroLS guidE
Vulcan
 Fryers
TEMPERATURE SETTING
 
displays
Press 
LEFT
 to increase temp.
Press 
RIGHT
 to decrease temp.
Press 
 to go to Step 5.
RIGHT TIMER
 displays
Press 
LEFT
 to increase time.
Press 
RIGHT
 to decrease time.
Press 
 to go to Step 4.
Display shows  
ACTUAL TEMPERATURE
MELT CYCLE
 displays
Press 
LEFT
 to change to  
“S”
 Solid.
Press 
LEFT
 to change to  
NO MELT
.
Press 
LEFT
 to change to  
“L”
 Liquid.
Press 
 to go to Step 6.
Results of programming for 
oil temperature is at set 
temperature
TEMPERATURE 
SETTING RESULTS
Press 
 program button 
to enter the program mode: 
LEFT TIMER
 displays
Press 
LEFT
 to increase time.
Press 
RIGHT
 to decrease time.
Press 
 to go to Step 3.
Press 
 button and 
HOLD 
FOR 3-5 seconds 
 to save 
and exit program mode.
Note: Programming modes can 
be initiated while the fryer is 
ON by pressing the 
 button. 
If ‘LOCKED’ appears refer to 
‘UNLOCK’ code.
UNLOCK
 displays
Press 
LEFT
 to 
LOCK
.
Press 
RIGHT
 to 
UNLOCK
.
Press 
 to go to Step 7.
Note: VULCAN recommends  
keeping the controls LOCKED after 
programming to prevent altering
2
3
4
5
6
7
To make changes 
to your program:
  
1. If display is 
locked it must be 
unlocked using the 
unlock code.  
2. After unlocking  
go to steps 
     –      
2
7
oPTionaL diSPLay modES
After the program mode is completed, one 
of the following screens will be displayed.
Results of programming 
MELT L
MELT CYCLE RESULTS
Display says 
MELT L
Results of programming 
MELT S
Display says 
MELT S
Results of programming 
NO MELT
Display says 
HEATING 
if oil 
temperature is below 135 º F