Hoshizaki KM-1400SWH/3-M User Manual

Page of 24
16
b) Connection to a Closed Loop System
• Condenser water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" nominal 
copper water tubing is recommended for the condenser water supply line.
• Condenser return outlet is 3/8" FPT. A minimum of 3/8" nominal copper water tubing is 
recommended for the condenser return line.
• Shut-off valves and drain valves should be installed at both the condenser water supply 
inlet and condenser return outlet.
• The water supply to the condenser should not drop below 4 GPM. 
• The pressure differential between the condenser water supply inlet and condenser return 
outlet must be no less than 10 PSIG.
• When using a glycol blend, the solution mixture should be less than 30% glycol.
• In order to maintain the proper high side pressure, the condenser water supply inlet 
temperature should not drop below 45°F (7°C) and the condenser return outlet 
temperature must be in the 104°F to 115°F (40°C to 46°C) range. Once the icemaker 
installation is complete, confirm the condenser return outlet temperature 5 minutes after a 
freeze cycle starts. If the condenser return outlet temperature is not in the proper range, 
use a flat blade screwdriver to rotate the adjustment screw on the water-regulating valve 
until the temperature is in the proper range (rotate counterclockwise to raise temperature 
or clockwise to lower temperature).
Fig. 10
KM-1400SWH/3-M 
Connection to a Closed Loop System
Separate piping to approved drain. 
Leave a 2-inch (5-cm) vertical air 
gap between the end of each pipe 
and the drain.
Icemaker Water Supply Line 
Shut-Off Valve
Icemaker Water Supply Line 
Drain Valve
Icemaker
Icemaker 
Water Supply 
Inlet
1/2" FPT
2-inch (5-cm) air gap
Floor Drain
Icemaker
Drain Outlet 
3/4" FPT
Bin
Condenser Water Supply Line 
Shut-Off Valve
Condenser Water Supply Line Drain Valve
Condenser Water 
Supply Inlet
1/2" FPT
Condensation 
Drain Outlet
3/8" OD Hard Tube
Minimum 1/2" Nominal Copper Water Tubing
Vent Tube
Vent Tube
Minimum 
3/4" Nominal 
Hard Pipe
Minimum 3/8" Nominal Copper Water Tubing
Condenser 
Return Outlet 
3/8" FPT
Condenser Return Line 
Shut-Off Valve
Condenser Return Line Drain Valve
Bin Drain Outlet
See Manufacturer's Instructions