C. Location
CAUTION
1. This icemaker is not intended for outdoor use. Normal operating ambient 
temperature should be within 45°F to 100°F (7°C to 38°C); Normal operating 
water temperature should be within 45°F to 90°F (7°C to 3°C). Operation 
of the icemaker, for extended periods, outside of these normal temperature 
ranges may affect icemaker performance.
. This icemaker will not work at sub-freezing temperatures. To prevent 
damage to the water supply line, drain the icemaker if the air temperature is 
going to go below 3°F (0°C). See "III.C. Preparing the Icemaker for Long 
Storage."
For best operating results:
• The icemaker should not be located next to ovens, grills, or other high heat producing 
equipment.
• The location should provide a firm and level foundation for the equipment.
• Allow 6" (15 cm) clearance at rear, sides, and top for proper air circulation and ease of 
maintenance and/or service should they be required.
D. Setup
1) Follow the dispenser unit/storage bin setup procedure.
) Position the dispenser unit/storage bin in the selected permanent location.
3) Place the icemaker on top of the dispenser unit/storage bin.
4) Secure the icemaker to the dispenser unit/storage bin using the  mounting brackets 
and the bolts provided. See Fig. . 
5) Level the icemaker and dispenser unit/storage bin in 
both the left-to-right and front-to-rear directions. If using 
a storage bin, adjust the storage bin legs to make the 
icemaker level.
6) Make sure the icemaker and dispenser unit/storage bin 
are properly secured. 
7) Seal as required by sanitation code.
8) Replace the panels in their correct positions.
Fig. 2
Icemaker
Bolts
Mounting 
Brackets
Bin