KCVR9NE 
 
 
FILTER SATURATION ALARM; 
RESETTING THE HOOD WORKING HOURS COUNTER 
• After the hood has been running for 100 hours the display shows FF, 
meaning that the GREASE FILTERS should be cleaned; 
• After 200 hours of running, the display shows EF, meaning that the 
GREASE FILTERS should be cleaned and the A.C. filter cartridges 
replaced (the latter warning appears only if  the A.C. FILTER alarm function 
has been enabled). 
NOTE: The warnings appear on the display only when the blower 
motor is off. 
Direct procedure for enabling/disabling remote control 
Turn off the motor and the lights and make sure that no alarms are on (filter 
saturation). Press and hold the DELAY button for about 5s, until: 
• “tc” flashes twice on the display, meaning that the remote control has 
been enabled; 
• “tc” flashes once on the display, meaning that the remote control has 
been disabled. 
 
 
SET-UP procedure 
The default configuration is as follows: 
• 400W motor powered by 230 VAC – 50/60 Hz; 
• A.C. FILTER saturation alarm disabled; 
• remote control disabled. 
ACCESSING THE SET-UP PROCEDURE: 
1) To access the set-up procedure press button 24 for about 5s, until  
an animation appears on the display; when the animation starts you have 
about 5 seconds to perform the set-up: 
• Press V- to enable/disable the A.C. filter saturation alarm EF flashes twice 
when enabled and once when disabled 

• Press button 24 to enable/disable the remote control receiver; 
“tc” flashes twice on the display when the remote has been enabled and 