Planning Information
Model W362418 (R) Pro Wall Hood
6
Dimensions in parentheses are in
millimeters unless otherwise specified.
Ducting considerations for
Pro 24" (610) deep wall
hoods.
DUCTWORK INSTALLATION
THROUGH ROOF
24" 
(610)
DEPTH OF HOOD
ROOF CAP OR REMOTE BLOWER
10" ROUND DUCT
SOFIT OR CABINET
OR DUCT COVER  
WALL CAP
OR REMOTE BLOWER
*HORIZONTAL DISCHARGE IS APPLICABLE ON 24" (610) DEEP WALL HOODS
USED WITH WBLOWER-60INT, WBLOWER-120INT OR ANY WOLF REMOTE BLOWER.
WBLOWER-90INT IS NOT FOR USE IN HORIZONTAL DISCHARGE APPLICATIONS.
  DUCTWORK INSTALLATION
THROUGH WALL
DISCHARGE COLLAR
HORIZONTAL
DISCHARGE*
VERTICAL DISCHARGE
  TRANSITION
 22
1
/
4
"W x 9"D TO 10" ROUND
10"H (INCLUDING FLANGES)
30" 
TO
 36"
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
 36" 
(914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
18" 
(457)
HEIGHT OF HOOD
WALL HOOD
D U C T I N G   C O N S I D E R A T I O N S
Wolf Pro 24" (610) deep wall hoods are shipped
without the blower assembly. Internal, in-line or
remote blower assemblies are available. The
remote blower can be mounted on the roof or an
exterior wall. Refer to the illustration below for
ducting options.
Pro 24" (610) deep wall hoods have an adjust-
able discharge location that can run vertically or
horizontally. Horizontal discharge is applicable
on 24" (610) deep hoods used with WBLOWER-
60INT or WBLOWER-120INT or any remote
blower. WBLOWER-90INT is not for use in hori-
zontal discharge applications.
Refer to the Pro ventilation charts at the end of
this section for recommendations and blower
options
.