Synchronous Operation Mode (AWG710B only)
3-254
AWG710&AWG710B Arbitrary Waveform Generator User Manual
Setting a Slave IP address
The IP address of Slave is registered into Master with the Edit Slave IP Address 
menu.
1. Push UTILITY (front-panel)!Comm (bottom) button of the AWG710B 
used as slave
2. Check and write the IP address of slave.
3. Push Connect (bottom)!Edit Slave IP Address...(side) button of the master 
AWG710B.
4. The Slave IP Address dialog box appears. Enter the IP address of the slave 
AWG710B.
5. Push the OK side button.
Testing the Network Connection
Complete the physical connection and settings, using the Execute Ping... menu 
verify that the slave AWG710B can be recognized correctly. The usage is the same 
as Execute Ping of the Comm bottom menu of a UTILITY screen. Refer to the 
Testing the Network Connection on  page 3-164 .
Table 3-58: Difference between AWG mode and synchronous operation mode
Bottom menu
Sync-Master
Sync-Slave
Waveform
/Sequence
Another waveform file cannot be 
loaded during output operation (RUN 
LED under lighting).
The loaded file cannot be edited.
Another waveform file cannot be 
loaded during output operation (RUN 
LED under lighting).
The loaded file cannot be edited.
Vertical
Horizontal
It controls by Master.
Run Mode
Gated mode cannot be used.
It controls by Master.
Trigger
It controls by Master.