Mitsubishi Electronics MR-J3-T User Manual

Page of 52
A.3
Alarms and Warning Messages
Appendix
Alarms and Warning Messages
MR-J3-T
A - 41
Display
Alarm Code
Error
Alarm Reset
ACD3
(Bit 3)
ACD2
(Bit 2)
ACD1
(Bit 1)
ACD0
(Bit 0)
Power
Supply
OFF
ON
MR-
Configurator/
HMI
Reset
(RES)
Alar
me
A10
0
0
1
0
Undervoltage
A12
0
0
0
0
Memory error 1
A13
0
0
0
0
Clock error
A15
0
0
0
0
Memory error 2
(E²PROM)
A16
0
1
1
0
Encoder error 1
(at power on)
A17
0
0
0
0
Board error
A19
0
0
0
0
Memory error 2
(Flash ROM)
A1A
0
1
1
0
Incorrect servo
motor
A20
0
1
1
0
Encoder error 2
A24
1
1
0
0
Main circuit error
A25
1
1
1
0
Absolute position
lost/erased
A30
0
0
0
1
Regenerative
braking overload
A31
0
1
0
1
Overspeed
A32
0
1
0
0
Overcurrent
A33
1
0
0
1
Overvoltage
A35
1
1
0
1
Input frequency
too high
A37
1
0
0
0
Parameter error
A45
0
0
1
1
Main circuit
overheat
A46
0
0
1
1
Servo motor
overheat
A47
0
0
1
1
Cooling fan error
A50
0
0
1
1
Overload 1
A51
0
0
1
1
Overload 2
Table A-3: Error messages(1)