KitchenAid 12828134 User Manual

Page of 56
27
PRODUCT DATA SHEETS
Interior Water Filtration System
Model 67003523-750 Capacity 750 Gallons (2839 Liters)
This system has been tested according to NSF/ANSI 42/53 for the reduction of the substances listed below. The concentration of 
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for 
water leaving the system, as specified in NSF/ANSI 42/53.
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 
71.6°F (20°C to 22°C).
It is essential that operational, maintenance, and filter 
replacement requirements be carried out for the product to 
perform as advertised.
The filter monitor system measures the amount of water that 
passes through the filter and alerts you to replace the filter. 
When 90% of the filter’s rated life is used, the yellow (Order) 
light comes on. When 100% of the filter’s rated life is used, 
the red (Replace) light comes on, and it is recommended that 
you replace the filter. Use replacement cartridge 67003523, 
part #4396395. 2005 suggested retail price of $49.99 U.S.A./
$65.95 Canada. Prices are subject to change without notice. 
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of 
unknown quality without adequate disinfection before or after 
the system. Systems certified for cyst reduction may be used 
on disinfected waters that may contain filterable cysts.
Refer to the back cover or “Accessories” section for the 
Manufacturer’s name, address and telephone number.
Refer to the “Warranty” section for the Manufacturer’s limited 
warranty. 
Application Guidelines/Water Supply Parameters
Substance Reduction
Aesthetic Effects
NSF Reduction 
Requirements
Average
Influent
Influent Challenge 
Concentration
Maximum
Effluent
Average
Effluent
Minimum%
Reduction
Average% 
Reduction
Chlorine Taste/Odor
Particulate Class I
*
50% reduction
85% reduction
1.88 mg/L
5,700,000 #/mL
2.0 mg/L ± 10%
At least 10,000 
particles/mL
0.06 mg/L
69,000 #/mL
**
0.05 mg/L
30,583 #/mL
96.84
98.94
>97.26
 99.52
Contaminant
Reduction
NSF Reduction 
Requirements
Average
Influent
Influent Challenge 
Concentration
Maximum
Effluent
Average
Effluent
Minimum%
Reduction
Average% 
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5
0.010 mg/L
0.010 mg/L
0.153 mg/L
0.150 mg/L
0.15 mg/L ± 10%
0.15 mg/L ± 10%
< 0.001mg/L
< 0.001mg/L
< 0.001mg/L
< 0.001mg/L
>99.29%
>99.29%
>99.35%
>99.33%
Mercury: @ pH 6.5
Mercury: @ pH 8.5
0.002 mg/L
0.002 mg/L
0.006 mg/L
0.006 mg/L
0.006 mg/L ± 10%
0.006 mg/L ± 10%
0.0005 mg/L
0.0015 mg/L
0.0003 mg/L
0.0008 mg/L
90.91
75.93
95.70
86.22
Toxaphene
0.003 mg/L
0.015 mg/L
0.015 ± 10%
< 0.001mg/L
< 0.001mg/L
91.67%
92.97%
Atrazine
0.003 mg/L
0.009mg/L
0.009 mg/L ± 10%
< 0.002 mg/L
< 0.002 mg/L 75.31%
76.99%
Asbestos
99%
155 MF/L
10
to 10
fibers/L
††
<1 MF/L
<1 MF/L
>99.99%
>99.99%
Live Cysts
Turbidity
>99.95%
0.5 NTU
166,500 #/L
10.7 NTU
50,000/L min. 
11 ± 1 NTU
<1 #/L
0.49 NTU
<1 #/L
0.31 NTU
>99.99
95.2
>99.99
97.09
Lindane
0.0002 mg/L
0.002 mg/L
0.002 ± 10%
< 0.0001mg/L
0.000 mg/L
96.50%
98.72%
Tested and certified by NSF International against NSF/ANSI Standard 
42 for the reduction of Chlorine Taste and Odor, Particulate Class I*; 
and against NSF/ANSI Standard 53 for the reduction of Lead, 
Mercury, Atrazine, Toxaphene, Cysts, Turbidity, Asbestos and Lindane.
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
35 - 100 psi (241 - 689 kPa)
33° - 100°F (1° - 38° C)
0.78 gpm (2.9 L/min.) @ 60 psi.
*
**
††
Class I particle size: >0.5 to <1 um
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
Fibers greater than 10 um in length
Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.