Lexmark C762 User Manual

Page of 402
PostScript
4-68
 
InstalledRam
integer
(Read-only) Indicated, in bytes, the total amount of installed 
printer memory (RAM) in the system.
Note: 
InstalledRam should not be confused with RamSize 
which is the amount of memory (RAM) available to the 
formatting interpreters and the graphics engine.
JobTimeout
integer
The value in seconds to which the user parameter 
JobTimeout
 is initialized at the beginning of each print job. If 
you set the system parameter 
JobTimeout
 to a negative 
value, it is ignored and the previous setting of 
JobTimeout
 is 
used. A value of 0 (zero) indicates that the timeout is infinite. 
If you set a number between 1 and 14, 15 is set.
Legal values: x = 0, 15 <= x <= 65355
languagelevel
integer
The value of 
languagelevel
 integer in systemdict always 
matches the value of this system parameter. If set to 2, the 
printer will behave as though /UseOldcopypage and 
/UseOldfonts are both true (regardless of their actual values). 
The latter two parameters will return their actual values when 
queried.
Legal Values: 2, 3
MaxDisplayAndSourceList
2
integer
(Read-only) This value is always the same value as 
InstalledRam
.
MaxDisplayList
integer
(Read-only) See Table C-4 on page C-9 for the default value 
of your printer.
MaxFontCache
integer
(Read-only) See Table C-4 on page C-9 for the default value 
of your printer.
MaxFormCache
integer
Maximum bytes occupied by the form cache.
Legal value: Any non-negative integer.
MaxImageBuffer
integer
(Read-only) See Table C-4 on page C-9 for the default value 
of your printer.
MaxOutlineCache
integer
(Read-only) See Table C-4 on page C-9 for the default value 
of your printer.
MaxPatternCache
integer
Maximum bytes occupied by the pattern cache.
Legal value: Any non-negative integer.
MaxPermanentVM
2
integer
(Read-only) See Table C-4 on page C-9 for the default value 
of your printer.
MaxRasterMemory
integer
(Read-only) See Table C-4 on page C-9 for the default value 
of your printer.
MaxScreenStorage
integer
(Read-only) See Table C-4 on page C-9 for the default value 
of your printer.
Table 4-10:   PostScript Emulation System Parameters (Continued)
Key
Type
Definition
1
 These parameters are Lexmark-specific and are in addition to the Adobe PostScript Language Supplement 2016.
2
 These parameters are available with the Adobe PostScript Language Supplement 3010.
3