Lexmark C762 User Manual

Page of 402
PostScript
4-69
 
MaxSourceList
integer
(Read-only) See Table C-4 on page C-9 for the default value 
of your printer.
MaxUPathCache
integer
Maximum bytes occupied by the user path cache.
Legal value: Any non-negative integer.
PageCount
integer
(Read-only) Total number of pages that have been printed.
PanelCode
1
string
(Read-only) Version of the operator panel code.
PrinterCode
1
string
(Read-only) Firmware version of the printer controller card.
PrinterName
string
Initialized from the printer name stored in NVRAM (the default 
name of the printer). If this parameter is set to a zero length 
string, the 
PrinterName
 is set to the value of the product 
string in 
statusdict
.
Legal value: Any string of 32 or fewer non-null characters.
RamSize
integer
(Read-only) Total amount of memory (in bytes) installed in the 
printer.
RealFormat
string
(Read-only) Preferred representation for real numbers in 
binary encoded tokens.
Revision
integer
(Read-only) The current revision level of the machine-
dependent portion of PostScript emulation.
SearchBuiltinFontsFirst
1
boolean
Controls the device search order the interpreter uses to 
locate fonts.
SerialNumber
1
string
(Read-only) Serial number of your printer.
StartJobPassword
string
(Write-only) Controls the ability of the 
startjob
 operator to 
alter initial Virtual Memory (VM).
Legal value: Any integer or string of 32 or fewer non-null 
characters. An integer is converted to a string.
StartupMode
integer
Controls the system start file (Sys/Start) during PostScript 
emulation initialization. Also, controls the job start file (Job/
Start) before each print job.
0
Disable use of Sys/Start file and Job/Start file.
1
Sys/Start file executes (if present on disk or flash).
10
Job/Start file executes before each user job.
11
Both files run (a combination of 1 and 10).
Legal Values: 0 <= x <= 255. Values other than the four listed 
are equivalent to 0.
Note: 
If both flash and disk have a Sys/Start file and Job/Start 
file, the value of the SearchOrder for the two devices 
determines which file is executed.
StaticRamSize
1
integer
(Read-only) Amount of static memory (in bytes) on the 
controller board.
Table 4-10:   PostScript Emulation System Parameters (Continued)
Key
Type
Definition
1
 These parameters are Lexmark-specific and are in addition to the Adobe PostScript Language Supplement 2016.
2
 These parameters are available with the Adobe PostScript Language Supplement 3010.
3