Graco 246008 User Manual

Page of 38
Programming the Meter
309497L
5
5.
The meter displays the appropriate programmed 
screen and a pop-up window displays on the PC 
indicating programming is complete. This process is 
repeated for each meter in the system.
6.
Once the information is programmed into the elec-
tronic meter, the meter can be connected to the dis-
pensing hose in the corresponding bay. If the meter 
will not be immediately connected temporarily label 
it with the corresponding meter number and location 
(i.e. Meter 1, Bay 1, 10W30). The label assures the 
correct meter is installed in the correct location in 
the system. After the meter is installed in the correct 
location, the label can be removed. See Meter 
Installation
 on page 6.
The PC software allows a 5 minute period to pro-
gram the meter. 
If the electronic meter is unable to communicate 
with the PC during programming, the message NO 
SIGNAL appears at the top of the meter display.
If a programmed meter is moved or if the pro-
grammed parameters need to be changed, the 
meter must be reprogrammed.
F
IG
. 2
If PC software revision is 2.01.29 or meter firmware 
revision is 2.00.053, meter will display 3 places to 
the right of the decimal rather than 2.