Graco 246008 User Manual

Page of 38
Programming the Meter 
6
309497L
Meter Installation
CAUTION
Failure to comply with the following installation 
requirements may result in warranty coverage 
being denied.
Fluid lines MUST be thoroughly flushed before 
installing Matrix meters
.
 See CleanLine Filtration 
System, Instruction Manual 310652.
All Matrix systems MUST use the Graco Clean-
Line System for initial flushing and ongoing oper-
ation for all service fluids. See CleanLine 
Filtration System, Instruction Manual 310652.
Pressure relief kits MUST be used on all pumps 
within the Matrix system to prevent over-pressur-
ization due to thermal expansion. See Pressure 
Relief Kits, Instruction Manual 308403. Select 
appropriate relief kits when using high pressure 
(1600 psi) CleanLine filters. Low pressure (900 
psi) CleanLine filters have a built-in pressure 
relief valve.
KEY
DESCRIPTION, See F
IG
. 3.
D
Thermal Pressure Relief Kit must be 
installed downstream from the pump. The 
Thermal Pressure Relief Kit will vary based 
on the pump selected
E
Fluid shut-off valves (two)
F
Air Regulator
G
CleanLine Filter System
H
Pump  *  †
J
Filter and Lubricator Assembly
K
Master Bleed Air Valve (ball valve)
* Do not use diaphragm pumps in a Matrix system.
† Special pump packages are required for anti-
freeze. See instruction manual 310650.
F
IG
. 3
D
E
F
G
H
J
K
ti5127