Trip Rod Repair 
(SDP5 & SDP15 Meters Only)
Disassembly
1. Relieve Pressure, page 9.
2. Use a Torx (T20) wrench to remove 4 corner screws 
(A) located on the bottom of the meter (F
IG
. 30). 
Keep these screws for reassembly.
3. Turn meter over and tilt cover back (F
IG
. 31). 
4. With your finger, carefully lift up clip (D) to discon-
nect battery lead (B) from battery module.
5. Unsnap solenoid lead (C) (F
IG
. 33).
F
IG
. 30
You will not be able to completely remove the cover 
until you disconnect the leads to the battery, sole-
noid and remove the reed switch PCB.
F
IG
. 31
A
A
ti11936a
ti11937a
B
C
F
IG
. 32
NOTICE
Do not use a screw driver or any other tool to lift up 
clip (D) when disconnecting battery lead (B) from bat-
tery module. If the clip is damaged or broken it cannot 
be repaired; you will have to replace the battery mod-
ule. Order Part No. 255197. 
F
IG
. 33
B
ti11938a
D
D
 
ti11939a
C