Y1-03-0222 Rev. C 
 
 
For additional software applications unrelated to the  installation, please refer to the Link2AIS™ Software user 
guide for technical support. 
 
11. 
Hardware installation 
 
 WARNING: The compass safe distance of this unit is 0.5m or greater for 0.3° deviation. 
 
WARNING: Do not connect the Nauticast™-B AIS unit to a main (line) AC electrical supply, as an electric 
shock or fire hazard could result. Length of data/power cable connection must not exceed 3 meters. 
 
CAUTION:  Do  not  connect  the  Nauticast™-B  AIS  unit  to  a  DC  supply  exceeding  15.6  V  or  reverse  the 
supply polarity. Damage to the unit may result. Ensure the power supply is limited in accordance with EN 60950-
1:2006 and protected with fuse or breakers not to exceed the specifications listed in this manual. 
 
Electrical connections 
 
  WARNING:  Only  the  data  and  power  cables  provided  with  the  Nauticast™-B  AIS  unit  should  be  used  to 
connect antennas, power and display devices so as to maintain the integrity of the enclosure.  
 
Please see the Appendix section of this manual for details of the power, data and RF cables supplied. 
 
Using the two co-axial leads supplied, connect the down-lead from a VHF antenna to the VHF antenna port and 
connect the down-lead of a GPS antenna to the GPS antenna port. Please see Appendix A for a block diagram 
of the antenna installation. 
 
If an external display unit (AIS capable chart plotter, MKD, etc.) is to be used, connect the data interface cable 
to  the  NMEA  port.  Depending  on  your  model  chart  plotter,  a  NMEA  multiplexer  capable  of  handling  AIS  data 
(38,400  baud)  may  be  required. 
Consult  the  chart  plotter  manufacturer‟s  support  materials  for  interface 
instructions. 
 
Click the 'Yes' button if the MMSI is correct. 
 
The  static  data  tab  will  be  updated  to  show  the 
newly  programmed  vessel  information.  The  MMSI 
number  will  be  displayed  with  a  grey  background 
to  indicate  that  it  has  been  programmed  and 
cannot be changed. 
CAUTION:  Do  not  install  the  Nauticast™-B  AIS  unit  in  an 
environment where it can be subject to excessive exposure to water. 
 
CAUTION:  The  Nauticast™-B  AIS  unit  is  designed  for  operation  in 
the  temperature  range  -25  °C  to  +55  °C.  Do  not  install  (or  use)  the 
Nauticast™-B AIS unit in environments which exceed this range.