ASAI-Ethernet
13-4
Issue  7 May 1998 
NOTE:
Lucent Technologies strongly recommends (both for security and 
performance reasons) that the Ethernet connectivity between the MFB and 
the set of hosts with which it will communicate be a separate LAN segment. 
Customers who do not follow this recommendation are subject to an 
unscrupulous person gaining access to the DEFINITY LAN Gateway 
application in order to commit toll fraud and/or tamper with the real-time 
aspects of CTI applications. (Toll fraud is the unauthorized use of your 
telecommunications system by an unauthorized third party. Under 
applicable law, the customer is responsible for paying for such unauthorized 
usage.) 
The serial cables attached to the TN2208 can be used for local and remote 
administration as well as maintenance support.These are RS232 ports that allow 
connectivity to a dumb terminal or to terminal emulation software on a PC. The 
amphenol connector and the serial cable attached to the TN2170 are not currently 
used.
The first serial cable attached to the TN2208 (labeled A in Figure 13-2) should be 
connected to a 9600 baud (or better) modem that allows remote access by Lucent 
Technologies services. This is a similar arrangement to the INADS port provided 
on DEFINITY ECS. To enhance customer security, the modem should be turned 
off except when access by Lucent Technologies is desired. The second serial 
cable attached to the TN2208 (labeled B in Figure 13-2) can be used for local 
administration.
Administrative Console Connectivity for MFB
The MFB is provided with two serial ports (labeled A and B in Figure 13-2) that 
provide access to the administrative logins. The first port labeled “A” is dedicated 
for remote access by Lucent Technologies Services. The second port labeled “B” 
may be connected to a dedicated terminal, or to a shared terminal through an 
“A-B” ECS. Additionally, once the LAN network administration is completed, the 
administrative application may also be accessed by the use of “telnet” from a 
remote system.
For customers who do not wish to have an additional, physical, permanent 
console, it is recommended that the MFB be initially administered using a 
temporary terminal, PC, or laptop. Once the LAN administration is completed, 
telnet may be used from any host attached to the isolated segment (such as the 
DEFINITY LAN Gateway client). This allows further (and ongoing) administrative 
access without the need for a permanent console terminal. The overall 
connectivity scheme is depicted in Figure 13-5.