Lucent Technologies 555-230-220 User Manual

Page of 522
Call Scenarios and Applications
A-34
Issue  7 March 1998 
External Call to VDN, Answered by a Local 
Station, and Transferred to a Lookahead Interflow 
VDN
This scenario shows the call flow for an incoming ISDN PRI call to VDN 5678 that 
is answered by extension 4555 in ACD split 3333 and subsequently transferred to 
lookahead interflow VDN 5008 (see Figure A-5). The call is accepted by the 
receiving ECS (ECS B), waits in queue until the vector announcement (VDN 
1222, vector N) and is abandoned by the caller while the call is alerting extension 
1567. The lookahead display information is the VDN name provided on the VDN 
administration form.
The transfer to VDN 5008 is completed before the call attempts the lookahead to 
ECS B. If the call had initiated the lookahead interflow before the transfer 
operation had been completed, the ASAI adjunct connected to ECS B would have 
received the extension 4555 as the calling party number instead of the original 
SID/ANI for the call.
Note that the Alerting Event Report received by the ASAI Adjunct Processor 
connected to ECS A is received only if the lookahead interflowed call receives 
alerting treatment (that is, wait hearing ringback/announcement or extension 
alerting) before the call is answered on ECS B. If the call waits with silence (for 
example, wait hearing silence) before ECS B applies ringback or answers the call, 
the ASAI Adjunct Processor connected to ECS A receives a 
Cut-Through/Progress Event Report. Subsequent Alerting and Connected Event 
Reports are provided, depending on the call treatment provided by vector 
processing.
The Connected Event Report received by the ASAI Adjunct Processor connected 
to ECS A is triggered by the ISDN Connect message received from ECS B. ECS 
B provides a single ISDN Connect message with the first answer treatment 
provided. For example, listening to music or to an announcement while the call is 
in vector processing triggers ECS B to send an ISDN Connect message to ECS A. 
ECS B does not send additional ISDN messages to ECS A for subsequent 
answers (for example, other announcements or answered by a station). 
Therefore, the ASAI Adjunct Processor connected to ECS A does not receive 
further answer/connect notifications for the call.
Also note that the ISDN called number received by the adjunct connected to ECS 
A is not the same as the VDN number, since ISDN digit manipulation has 
occurred.
Assume that VDNs 5678 and 5008 are monitored over CRVs 98 and 80, 
respectively, by an ASAI Adjunct Processor connected to ECS A and that VDNs 
1111 and 1222 are monitored over CRVs 20 and 26, respectively, by an ASAI 
Adjunct Processor connected to ECS B. Messages in italics refer to messages 
exchanged by ECS B and the ASAI Adjunct Processor connected to ECS B.