ASAI and Release 6 Requirements
B-5
Issue  7 March 1998 
If the CRV values are administered to a single byte, then the 
adjunct may initiate and have active 127 simultaneous 
associations on any given ASAI interface (subject to 
availability of resources set by the other system parameters). 
If the CRV values are set at 2 bytes, the maximum number 
of associations
 is limited by the availability of other ECS 
resources, not the number of CRVs (32,767). That is, the 
maximum number of associations that the ECS can support 
over all ASAI interfaces (combined) is less than the number 
of available CRVs when a 2-byte CRV length is administered. 
The demands on other ECS resources prevent an adjunct 
from ever reaching the theoretical maximum of 32,767.