DELL 7.4 User Manual

Page of 232
Event ID — 2258
Description
Controller has preserved cache.
Severity
Warning /Non-critical
Cause and 
Action
Cause: I/O interrupted for a virtual disk which is connected to the controller.
Action: Check for foreign configuration and import if any. Check for cable fault. 
Recover any virtual disk lost by the controller.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap 
Numbers
753
Event ID — 2259
Description
An enclosure blink operation has initiated.
Severity
OK / Normal / Informational
Cause and 
Action
Cause: This alert is for informational purposes.
Action: None
Related Alert 
Information
Clear Alert Number: 2260
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap 
Numbers
851
Event ID — 2260
Description
An enclosure blink has ceased.
Severity
OK / Normal / Informational
Cause and 
Action
Cause: This alert is for informational purposes.
Action: None
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap 
Numbers
851
127