Event ID — 2264
Description
A device is missing.
Severity
Warning / Non-critical
Cause and 
Action
Cause: The controller cannot communicate with a device. The device may be 
removed. There may also be a bad or loose cable.
Action: Check if the device is in and not removed. If it is in, check the cables. Also 
check the connection to the controller battery and the battery health. A battery 
with a weak or depleted charge may cause this alert.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2050, 2060, 2070, 2080, 2090, 2100
SNMP Trap 
Numbers
753,803,853,903,953,1003,1053,1103,1153,1203
Event ID — 2265
Description
A device is in an unknown state.
Severity
Warning / Non-critical
Cause and 
Action
Cause: The controller cannot communicate with a device. The state of the device 
cannot be determined. There may be a bad or loose cable. The system may also be 
experiencing problems with the application programming interface (API). There 
could also be a problem with the driver or firmware.
Action: Check the cables. Check if the controller has a supported version of the 
driver and firmware. You can download the current version of the driver and 
firmware from the support site. Rebooting the system may also resolve this 
problem.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: 2048, 2050
Local Response Agent (LRA) Number: 2050, 2060, 2070, 2080, 2090, 2100
SNMP Trap 
Numbers
753, 803, 853, 903, 953, 1003, 1053, 1103, 1153, 1203
Event ID — 2266
Description
Controller log file entry: %1
Severity
OK / Normal / Informational
Cause and 
Action
Cause: The %1 indicates a substitution variable. The text for this substitution 
variable is generated by the controller and is displayed with the alert in the alert log. 
This text can vary depending on the situation. This alert is for informational 
purposes.
Action: None