DELL 7.4 User Manual

Page of 232
Event ID — 2304
Description
An attempt to hot plug an EMM has been detected. This type of hot plug is not 
supported.
Severity
OK / Normal / Informational
Cause and 
Action
Cause: This alert is for informational purposes.
Action: None
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: 2211
Local Response Agent (LRA) Number: None
SNMP Trap 
Numbers
751
Event ID — 2305
Description
The physical disk is too small to be used for a rebuild.
Severity
Warning / Non-critical
Cause and 
Action
Cause: The physical disk is too small to rebuild the data.
Action: Remove the physical disk and insert a new physical disk that is the same 
size or larger than the disk that is being rebuilt. The new physical disk must also use 
the same technology (for example, SAS or SATA) as the disk being rebuilt. If the 
rebuild does not start automatically after you have inserted a suitable physical disk, 
then run the Rebuild task. See the Server Administrator Storage Management User’s 
Guide
 for more information.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: 2326
Local Response Agent (LRA) Number: 2070
SNMP Trap 
Numbers
903
Event ID — 2306
Description
Bad block table is 80% full.
Severity
Warning / Non-critical
Cause and 
Action
Cause: The bad block table is used for remapping bad disk blocks. This table fills, as 
bad disk blocks are remapped. When the table is full, bad disk blocks can no longer 
be remapped, and disk errors can no longer be corrected. At this point, data loss 
can occur. The bad block table is now 80% full.
Action: Back up your data. Replace the disk generating this alert and restore from 
back up.
143