DELL 7.4 User Manual

Page of 232
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: 2307
Local Response Agent (LRA) Number: 2070
SNMP Trap 
Numbers
903
Event ID — 2307
Description
Bad block table is full. Unable to log block %1.
Severity
Critical / Failure / Error
Cause and 
Action
Cause: The bad block table is used for remapping bad disk blocks. This table fills, as 
bad disk blocks are remapped. When the table is full, bad disk blocks can no longer 
be remapped and disk errors can no longer be corrected. At this point, data loss 
can occur. The %1 indicates a substitution variable. The text for this substitution 
variable is displayed with the alert in the alert log and can vary depending on the 
situation.
Action: Replace the disk generating this alert. If necessary, restore your data from 
backup.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: 2048
Local Response Agent (LRA) Number: 2071
SNMP Trap 
Numbers
904
Event ID — 2309
Description
A physical disk is incompatible.
Severity
Warning / Non-critical
Cause and 
Action
Cause: You have attempted to replace a disk with another disk that is using an 
incompatible technology. For example, you may have replaced one side of a mirror 
with a SAS disk when the other side of the mirror is using SATA technology.
Action: See the hardware documentation for information on replacing disks.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap 
Numbers
903
Event ID — 2310
Description
A virtual disk is permanently degraded.
144