DELL 7.4 User Manual

Page of 232
Event ID — 2342
Description
The Check Consistency found inconsistent parity data. Data redundancy may be 
lost.
Severity
Warning / Non-critical
Cause and 
Action
Cause: The data on a source disk and the redundant data on a target disk is 
inconsistent.
Action: Restart the Check Consistency task. If you receive this alert again, check 
the health of the physical disks included in the virtual disk. Review the alert 
messages for significant alerts related to the physical disks. If you suspect that a 
physical disk has a problem, replace it and restore from backup.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: 2341, 2343
Local Response Agent (LRA) Number: 2080
SNMP Trap 
Numbers
1203
Event ID — 2343
Description
The Check Consistency logging of inconsistent parity data is disabled.
Severity
Warning / Non-critical
Cause and 
Action
Cause: The Check Consistency can no longer report errors in the parity data.
Action: See the hardware documentation for more information.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2080
SNMP Trap 
Numbers
1203
Event ID — 2344
Description
The virtual disk initialization terminated.
Severity
Warning / Non-critical
Cause and 
Action
Cause: A user has cancelled the virtual disk initialization.
Action: Restart the initialization.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2080
156