DELL 7.4 User Manual

Page of 232
Cause and 
Action
Hardware RAID: Cause and Action
Cause: You are attempting to rebuild data that resides on a defective disk.
Action: Replace the source disk and restore from backup.
Software RAID:
• Perform a backup with the Verify option.
• If the file backup fails, try to restore the failed file from a previous backup.
• When the backup with the Verify option is complete without any errors, delete 
the Virtual Disk.
• Recreate a new Virtual Disk with new drives.
• Restore the data from backup.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: 2195, 2346
Local Response Agent (LRA) Number: 2071
SNMP Trap 
Numbers
904
Event ID — 2348
Description
The rebuild failed due to errors on the target physical disk.
Severity
Critical / Failure / Error
Cause and 
Action
Cause:You are attempting to rebuild data on a disk that is defective.
Action: Replace the target disk. If a rebuild does not automatically start after 
replacing the disk, initiate the Rebuild task. You may need to assign the new disk as 
a hot spare to initiate the rebuild.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: 2195, 2346
Local Response Agent (LRA) Number: 2071
SNMP Trap 
Numbers
904
Event ID — 2349
Description
A bad disk block could not be reassigned during a write operation.
Severity
Critical / Failure / Error
Cause and 
Action
Cause: A write operation could not complete because the disk contains bad disk 
blocks that could not be reassigned. Data loss may have occurred and data 
redundancy may also be lost.
Action: Replace the disk.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: 2346
158