DELL 7.4 User Manual

Page of 232
Event ID — 2064
Description
Virtual disk rebuild started.
Severity
OK / Normal / Informational
Cause and 
Action
Cause: This alert is for informational purposes.
Action: None
Related Alert 
Information
Clear Alert Number: 2091
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap 
Numbers
1201
Event ID — 2065
Description
Physical disk rebuild started.
Severity
OK / Normal / Informational
Cause and 
Action
Cause: This alert is for informational purposes.
Action: None
Related Alert 
Information
Clear Alert Number: 2092
Related Alert Number: 2099, 2121, 2196
Local Response Agent (LRA) Number: None
SNMP Trap 
Numbers
901
Event ID — 2067
Description
Virtual disk check consistency cancelled.
Severity
OK / Normal / Informational
Cause and 
Action
Cause: The check consistency operation was cancelled because a physical disk in 
the array has failed or because a user cancelled the check consistency operation.
Action: If the physical disk failed, then replace the physical disk. You can identify 
which disk failed by locating the disk that has a red “X” for its status. Perform a 
rescan after replacing the disk. The consistency check can take a long time. The 
time it takes depends on the size of the physical disk or the virtual disk.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
64