DELL 7.4 User Manual

Page of 232
SNMP Trap 
Numbers
1201
Event ID — 2076
Description
Virtual disk Check Consistency failed.
Severity
Critical / Failure / Error
Cause and 
Action
Cause: AA physical disk included in the virtual disk failed or there is an error in the 
parity information. A failed physical disk can cause errors in parity information.
Action: Replace the failed physical disk. You can identify which disk has failed by 
locating the disk that has a red “X” for its status. Rebuild the physical disk. When 
finished, restart the check consistency operation.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap 
Numbers
1204
Event ID — 2077
Description
Virtual disk format failed.
Severity
Critical / Failure / Error
Cause and 
Action
Cause: A physical disk included in the virtual disk failed.
Action: Replace the failed physical disk. You can identify which physical disk has 
failed by locating the disk that has a red X for its status. Rebuild the physical disk. 
When finished, restart the virtual disk format operation.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap 
Numbers
1204
Event ID — 2079
Description
Virtual disk initialization failed.
Severity
Critical / Failure / Error
Cause and 
Action
Cause: A physical disk included in the virtual disk has failed or a user has cancelled 
the initialization.
Action: If a physical disk has failed, then replace the physical disk
66