DELL 7.4 User Manual

Page of 232
SNMP Trap 
Numbers
1204
Event ID — 2082
Description
Virtual disk rebuild failed.
Severity
Critical / Failure / Error
Cause and 
Action
Cause: A physical disk included in the virtual disk has failed or is not functioning. A 
user may also have cancelled the rebuild.
Action: Replace the failed or non-functional disk. You can identify a disk that has 
failed by locating the disk that has a red X for its status. Restart the virtual disk 
rebuild.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: 2048
Local Response Agent (LRA) Number: 2081
SNMP Trap 
Numbers
1204
Event ID — 2083
Description
Physical disk rebuild failed.
Severity
Critical / Failure / Error
Cause and 
Action
Cause: A physical disk included in the virtual disk has failed or is not functioning. A 
user may also have cancelled the rebuild.
Action: Replace the failed or non-functional disk. You can identify a disk that has 
failed by locating the disk that has a red X for its status. Rebuild the virtual disk 
rebuild.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2071
SNMP Trap 
Numbers
904
Event ID — 2085
Description
Virtual disk check consistency completed.
Severity
OK / Normal / Informational
Cause and 
Action
Cause: This alert is for informational purposes.
Action: None
68