Install and Wire Telephones and Other Equipment
9-2
Issue 1  September 1995  
auxiliary connector. When possible, the primary console should be powered 
from the system cabinet so it has the same power failure backup as the system 
itself.
The maximum cabling distance for the console powered from the cabinet is 350 
feet (100 meters).
The general steps to connect a telephone are as follows: 
1.
Choose a telephone or peripheral to connect such as Attendant 
Console 302B.
2.
Choose the port circuit pack to use (from circuit pack information 
provided in Table 9-7 on page 9-13) and its carrier and slot number. 
(TN754, Cabinet 1, Carrier C, Slot 02).
3.
Choose a port circuit on the port circuit pack (such as Port 05).
4.
Install cross-connect jumpers to wire the named pinouts on the terminal 
to the like-named pinouts on the port board, as shown in Table 9-1 and 
Figure 9-1.
This pinout information is taken from Table 9-7 for the 302B 
(4-wire) and Table 9-8 and Table 9-9 for the TN754B circuit pack.
5.
Administer on the console screen of the Management Terminal (G3-
MT).
The wiring designations are listed in Table 9-1 and are illustrated in Figure 9-1.
The following diagram illustrates these wiring designations.
Table 9-1.
302B to TN754 Wiring Designations
302B, 4-wire
TN754 (position 1C02)
Pin 
Name
Port 5 Name
4-wire Connector Pin 
Number 
1
txt
txt5
39
2
txr
txr5
14
3
pxt
pxt5
40
6
pxr
pxr5
15