Emerson 36J22 User Manual

Page of 24
36J22, 36J24, 36J54 and 36J55
DSI and HSI Single and Two Stage 
Combination Gas Valves
INSTALLATION INSTRUCTIONS
Operator:  Save these instructions for future use!
The 
36J22/24/54/55 combination gas valves are de-
signed for direct spark ignition (DSI) and hot surface 
ignition (HSI) system applications. These valves 
are equipped with redundant and main solenoid 
valves that control gas flow to the main burners, a 
pressure regulator and a two-position on/off switch 
for regulation and electrical shut-off of the solenoid 
valves. The 
36J24 and 36J55 are also equipped 
with a slow-opening pressure regulator for softer 
lighting characteristics. When the second solenoid  
on 
2-stage valves is energized the valve operates 
at the second stage (high) outlet pressure setting.
Type of Gas:  Natural gas 
           LP gas (use conversion kit)
Ambient Temperature:  -
40° to 175°F
Pressure Rating:  
14" W.C. (½ PSI) max.
Voltage:  
24 VAC
Frequency:  
50/60 Hz
Current:  Single Stage – 
0.28A
 
      Two-Stage – 
0.43A
Mounting Positions:  Multipoise – Control may 
 
       
   be mounted in any position 
CONTENTS
Description  ........................................................ 
1
Specifications  .................................................... 
1
Precautions  ....................................................... 
2
Installation 
 
System Wiring ...................................... 
3
Adjustment 
 
Pressure Regulator Adjustment ............ 
6
Lighting Instructions ..........................................
Contents French
 ................................................
9
Contents Spanish
 ............................................
17
36J Two-Stage
36J Single Stage
PIPE SIZES/CAPACITIES
Pipe Sizes 
Available
(inches)
1/2" x 1/2" NPT 
140,000
AGA Std. Nat. Gas
(
1,000 BTU/cu. ft.)
226,800
LP Gas
(
2,500 BTU/cu. ft.)
Capacity (BTU/hr) at
1” pressure drop across valve
Fig. 
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY 
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE 
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
 
 
SPECIFICATIONS
 
 
DESCRIPTION
PART NO. 
37-7338A
1224
www.white-rodgers.com
www.emersonclimate.com
Model 
Number
Coil 
Voltage
Stages
Opening
Characteristics
Intermittent Pilot
Proven Pilot
HSI
DSI
Standing 
Pilot
36J22
24V
1
Fast
No
Yes
Yes
No
36J24
24V
1
Slow
No
Yes
Yes
No
36J54
24V
2
Fast
No
Yes
Yes
No
36J55
24V
2
Slow
No
Yes
Yes
No
Pressure Regulator Adjustment Range (in W.C.)
Two Stage
Gas 
Type
Single 
Stage
Low
High
Min. Diff.
Low to High
Natural 2.5 – 5.0 1.0 – 4.0 2.0 – 5.0
1
LP
7.0 – 12.0 4.0 – 10.0 6.0 – 12.0
2