Emerson 36J22 User Manual

Page of 24
2
PRECAUTIONS
 
SPECIFICATIONS
 
1.  Failure to turn off electric or main gas
supply to heating system could cause 
personal injury and/or property damage 
by shock, gas suffocation, fire, and/or
explosion.
2.  Do not use this control on circuits 
exceeding specified voltage. Higher
voltage will damage the control and may 
cause shock or fire hazard.
3.  NEVER USE FLAME OR ANY KIND OF 
SPARK TO CHECK FOR GAS LEAKS–
COULD CAUSE FIRE AND/OR EXPLOSION.
4.  Do not use a control set for natural gas 
with LP gas, or a control set for LP gas 
with natural gas. Personal injury and/or 
If you do not follow these instructions exactly, a fire or explosion
may result, causing property damage, personal injury or loss of life.
property damage, gas suffocation, fire,
and/or explosion may result.
5.  Do not use a gas valve which appears to be 
damaged. A damaged valve may cause  
personal injury and/or property damage 
due to shock, gas suffocation, fire and/or
explosion. Contact supplier to replace any 
valve that appears to have been damaged.
6.  Do not use a gas valve that has been in 
direct contact with water. Water entering 
gas valve may result in concealed internal 
damage to gas valve. Personal injury and/
or property damage, gas suffocation, fire
and/or explosion may result.
WARNING
!
DO NOT BEGIN INSTALLATION UNTIL YOU READ THE FOLLOWING 
PRECAUTIONS.
WARNING
!
Properly install gas piping to control. 
•  Do not remove protective inlet or outlet caps until ready to connect supply pipe to gas valve.
•  Use new supply pipe, properly threaded, reamed, de-burred, and cleaned.
•  Use backup wrench, applied only to provided wrench flats on inlet boss, when tightening the
supply pipe. Do not grip bracket, solenoid or any other part of control.
•  Do not over-tighten pipe to control (
50ft-lbs max.)
•  Always install sediment trap in the gas supply line to prevent contamination of gas valve.
Failure to install properly can cause gas leakage resulting in injury due to fire or explosion.
CAUTION
!
1.  Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring 
can cause equipment damage, property damage, and/or personal injury.
2.  This control is not intended for use in locations where it may come in direct contact with water.  
Suitable protection must be provided to shield the control from exposure to water (dripping, 
spraying, rain, etc.). 
3.   Clean gas piping of contaminants, cutting fluid, or other chemicals which might react harm-
fully with the gas valve components before install.
Parts and Accessories:
 
Natural to Regulated LP Gas Conversion Kits
 
• 
F92-0659 for Single Stage
 
• 
F92-1008 for Two-Stage
 
Natural to Unregulated LP Gas Conversion Kit
 
• 
F92-0737
 
LP to Natural Gas Conversion Kits
 
• 
F92-0656 for Single Stage
 
• 
F92-1011 for Two-Stage
Note: Two single stage kits may be used for two-
stage valve