FIREPLACE 
INSTALLATION
ELECTRICAL SUPPLY CONNECTION
  CAUTION:  Disconnect  the 
electrical  power  to  the  supply 
circuit before attempting to con-
nect or service this appliance.
  WARNING:  This  appliance, 
when installed must be electri-
cally  grounded  in  accordance 
with  local  code  or  in  the  ab-
sence  of  local  code,  with  the 
current National Electric Code, 
ANSI/NFPA 70, or the Canadian 
Electric Code, CSA C22.1.
A pre-wired junction box receptacle with strain 
relief is provided on the right side of the cabinet 
for hard wiring the unit to a 15 Amp, 120VAC, 
60Hz grounded branch circuit. If the installation 
demands that the electrical supply be connected 
from the left side, the entire receptacle box can 
be relocated to the left side by following these 
instructions:
Note:
 If you do not need to relocate the junction 
box, to connect the electric supply follow steps 8 
through 11 only:
1.  Remove 2 screws and outer cover with strain 
relief bushing on right side of cabinet (see 
Figure 34).
2.  Remove inner retaining screw  on junction 
box mounting tab.
3.  Slide junction box up until screw mounting 
tab is lined up to notch in outer cabinet.
4.  Swing the junction box out and slip retaining 
flange out through the slot in outer cabinet.
5.  Remove two screws and outer cover on the 
left side of the outer cabinet.
6.  Reinsert junction box retaining flange through 
slot now on the left side and swing screw 
mounting tab back through notch as before.
7.  Slide the junction box down till mounting tab 
holes line up and replace the inner retaining 
screw.
8.  With junction box cover removed, pull the 
end of 3-wire Romex supply line through 
universal strain relief bushing on cover. (see 
Figure 34).
9.  Strip back the outer Romex to about 4" and 
connect black, white and green wires accord-
ingly using 3 wire nut connectors.
10.  Tuck  tailing  wires  into  junction  box  and 
replace junction box cover using 2 remaining 
screws.
11.  Tighten down strain adjustment on universal 
bushing until Romex sheathing is secured.
The electrical connection is now complete.
Figure 34 - Relocating Junction Box 
Receptacle and Electrical Supply 
Connection
J-Box Cover 
with Strain 
Relilef
J-Box 
Cover
Romex 
Cable
J-Box with 
Receptacle
J-Box Cover with 
Strain Relief
Screw/Tab 
Retainer
INSTALLING OPTIONAL BLOWER 
ACCESSORIES
NOTICE: If installing blower in 
an  existing  fireplace  with  gas 
connections, shut off gas sup-
ply and disconnect heater from 
gas supply. Contact a qualified 
service person to do this.
 WARNING: If there is a du-
plex  electrical  outlet  installed 
in the right side of the bottom 
of  the  fireplace  base  area,  be 
sure  that  the  electrical  power 
to the outlet is turned off before 
proceeding with blower instal-
lation.  Failure  to  do  this  may 
result in serious injury.
Model BK Installation
Follow all instructions provided in the blower 
accessory kit.
1.  Attach power cord to blower motor by firmly 
pushing the two female terminals at the end of 
power cord onto the two spade terminals on 
blower motor (see Figure 35, page 22).